top.gif (1082 bytes)
Promo Systems
Burglar Alarms
Fire Alarms
Monitoring
Closed Circuit TV
Card Access
Card Access
Central Vac
Commercial Audio
Home
Satellite


 


Multiple Keypads

* Four different keypads available
* connect up to 8 keypads to panel
* PC5508 standard 8 zone LED keypad
* PC5516 standard 16 zone LED keypad
* PC5532 standard 32 zone LED keypad
* LCD5500 alphanumeric keypad

Zone Expansion

* expand from 8 to 32 zones
* 2 partitions


Hard Wire

* PC5108 - 8 zone expansion module
* PC5108D - 16 zone expansion module utilizing zone doubling


Wireless
* PC5132-900 - wireless zone expansion module
* connect up to 32 wireless zones


Output Options
* up to 4 high current outputs

    PC5204

      - 4 output high current power supply module
      - 1 output fully supervised for siren output

* up to 8 voltage outputs

    PC5208

      - 8 output transistor switch module (50 mA)


Advanced Communications

* supports all major formats including SIA and Contact ID
* LINKS cellular communication
* event initiated personal paging
* 3 phone numbers, 2 account numbers


Audio Capability

* supports Central Station Two Way Voice and Home Intercom features


Efficient Installation

* 4 wire communications bus (KEYBUS)

    - connect modules up to 1000' (330m) from control panel
    - up 10 1.5A auxiliary power
    - PC5204 - 4 output high current power supply module provides up to 1A auxiliary power
    - main panel provides up to 500mA auxiliary power


PC5010 Main Control Panel

* up to 32 fully programmable zones

    - 8 zones on main control panel (16 with zone doubler option)
    - hard wire zones and wireless expansion
    - all zones programmable as burglary or fire
    - assign zones to one or both partitions
    - zone options include: End of Line (EOL) resistor, Double EOL resistor,
      Normally Closed loops or Zone Doubling
    - 24 programmable zone types

* 2 partitions

    - most features programmable by partition
    - 32 - 4 or 6 digit access codes assignable to one or both partitions
    - 1 system master code, 2 partition master codes, and duress codes

* 128 event buffer

    - all events automatically stored with time and date stamp to buffer
    - events can be printed on-site, viewed through the LCD Keypad or DLS software

* alarm output

    - bell ouput - 700A @ 12Vdc, PTC protected
    - additional supervised siren output using PC5204 power supply module,
      1A @ 12Vdc, PTC protected

* programmable voltage outputs

    - main panel PGM2 - high current switch to ground (can also be used for 2 wire smoke)
    - main panel PGM1 - low current, 50mA @ 12Vdc
    - additional low current voltage outputs using PC5208 output module, 50mA @ 12Vdc
    - additional high current voltage outputs using PC5204 power supply module,
       1.0A @ 12Vdc

* upload / download capability

    - program system using DLS software
    - view status and trouble conditions
    - view 128 event buffer

* power capacity

    - 500 mA @ 12.5Vdc (400 mA for UL applications)
    - separately fused battery and bell output
    - positive temperature coefficient (PTC) AUX & Bell output protection
    - electronic protection of KEYBUS
    - supervision of AC power loss, low battery, auxiliary failure

* battery required

    -12V, 4 Ah, rechargeable gel-cell

* transformer required

    -16.5 Vac, 40VA


System Operation

* up to 2 partitions

    - each partition acts as a separate alarm system with any number of zones,
       user codes, keypads and individually programmable features

* 32 access codes

    - each partition can have any number of user codes which may be enabled to work
       on one or both partitions
    - programmable system access by user code
    - individual open / close reporting by user

* automatic arming by partition

    -each partition may be programmed to auto-arm at different times

* 'quick arm' and 'quick exit'

    -allows users to arm and exit easily

* Home-Away zones and At-Home arming

    -security of perimeter arming while premise is occupied

* door chime

    -programmable by zone
    -monitor a door by having keypad beep when the door is opened and closed


False Alarm Prevention

* audible exit delay
* audible exit fault
* programmable swinger shut down by zone
* programmable transmission delay by zone
* opening after alarm transmission



Full Supervision

Trouble conditions are displayed on all keypads and can also be communicated to central station for:

* low battery
* auxiliary power failure
* siren circuit trouble
* buffer near full capacity
* loss of AC power
* zone tamper
* fire circuit trouble
* failure to communicate
* telephone line trouble - (via links cellular communicator)
* KEYBUS module communication failure
* PC5204 power supply module low battery
* PC5204 power supply module AC power loss


HARRIS SECURITY SYSTEMS

1807 Highway 231 South, Ozark, Alabama
toll free: 800-240-1717  fax: 334-445-1341
dothan 794-0079 - troy 566-8988 - eufaula 687-8985 - ozark 774-8564

email. sales@harrissecurity.com